RMS Construction Class Codes

 

Touchstone supports the following RMS construction class (RMS) codes:

RMS Code

Corresponding AIR Construction Code

Description

0

100

Unknown

1

101

Wood

1A

102

Mobile Homes without Tie Downs

1A1

102

Conventional - Multiple Span Bridges (less than 500 feet)

1A2

102

Conventional - Continuous Bridges (less than 500 feet)

1B

104

Major Bridges (greater than 500 feet)

1B1

104

Underground Pipelines

1B2

104

At Grade Pipelines

1C1

101

Timber Frame with Tiled Roof

1C2

101

Timber Frame with Flat Roof

1C3

101

Timber Frame with Thatch Roof

2

111

Light Wood Frame

2A

111

Concrete Dams

2A1

113

Earthfill and Rockfill Dams

2A2

112

Alluvium Tunnels

2B

114

Rock Tunnels

2B1

114

Cut and Cover Tunnels

2B2

114

Underground Liquid Tanks

2B3

114

Underground Solid Tanks

2B7

114

Unreinforced Solid Masonry - with Rigid Diaphragms

2C

116

On Ground Liquid Tanks

2C1

118

On Ground Solid Tanks

2C2

115

Elevated Liquid Tanks

2D1

111

Masonry with Steep Tiled Roof

2D2

111

Masonry with Low Slope Tiled Roof

2D3

111

Masonry with Flat Roof

2D4

111

Masonry with Thatch Roof

3

131

Light Wood Stud Walls

3A

131

Elevated Solid Tanks

3A1

134

Railroads

3A2

132

Highways

3A3

135

Runways

3A4

133

Masonry Chimneys

3A5

135

Concrete Chimneys

3A6

134

Steel Chimneys

3A7

100

Concrete Piloti

3A8

100

Concrete Filled Tube (CFT)

3A9

100

Gravity Load Designed RC with Unreinforced Masonry Infill

3A10

131

Reinforced Concrete Frame with Wood Frame in the Upper Floors

3B

137

Cranes

3B1

137

Conveyor Belts

3B2

137

Electrical Transmission - Conventional (less than 100 feet)

3B3

137

Electrical Transmission - Major (less than 100 feet)

3B4

136

Broadcast Towers

3B5

137

Observation Towers

3B6

135

Offshore Towers

3C

131

Reinforced Concrete with Wood or Metal Roof Deck

3C1

131

Reinforced Concrete with Tiled Roof

3C2

131

Reinforced Concrete with Flat Roof

4

151

Light Wood Post and Barn

4A

151

Waterfront Structures

4A1

155

Residential Equipment

4A2

155

Office Equipment

4A3

155

Electrical Equipment

4A4

153

Mechanical Equipment

4A5

153

High Technology Equipment

4A6

100

Gravity Load Designed Steel with Unreinforced Masonry Infill

4A7

151

Steel Frame with Wood Frame in the Upper Floors

4B

152

Trains, Trucks, Airplanes, etc.

4B1

152

Personal Auto

4B2

152

Auto Dealers

4C

151

Steel Frame with Wood or Metal Roof Deck

4C1

151

Steel Frame with Tiled Roof

4C2

151

Steel Frame with Flat Roof

5

191

Heavy Timber

5A

192

Pumping Stations

5B

194

Compressor Stations

6

201

Heavy Timber Frame

7

202

Heavy Timber Frame with URM Infills

8

203

Masonry

9

227

Weak Masonry

10

228

Rubble Stone Masonry

11

211

Adobe

12

212

Unreinforced Masonry (URM)

13

213

Unreinforced Cut Stone Masonry

14

214

Unreinforced Solid Brick Masonry

15

215

Unreinforced Concrete Block Masonry

16

221

Structual Masonry

17

222

Reinforced Masonry

18

223

Confined Masonry

19

224

Reinforced Concrete

20

225

Cast-In-Place Reinforced Concrete

21

226

RC MFR

22

204

RC MFR with Shear Walls

23

205

RC MFR with URM Infills

24

206

RC Shear Wall

25

231

Waffle or Flat Slab

26

232

Steel and Reinforced Composite Frame

27

233

Precast Reinforced Concrete

28

253

Precast MRF

29

254

Precast with Shear Walls

30

234

Precast with URM Infill

31

235

Tilt-Up

32

236

Precast Panel Bearing Walls (Non Tilt-Up)

33

237

Lift Slab

34

238

Steel

35

255

Steel Frame

36

256

Steel MFR

37

257

Steel MRF with Shear Walls

38

241

Steel MFR with URM Infill

39

242

Concentrically Braced Steel Frames

40

243

Eccentrically Braced Steel Frames

41

244

Light Metal

42

245

Light Metal Frames

43

246

Light Metal Frames with URM Infill

44

261

Mobile Homes

45

261

Mobile Homes with Tie Downs

46

100

Petrochemical Facilities

46A

100

Oil Refineries and Petrochemical Plants

46B

100

Tank Farms

46C

251

Canals

46D

227

Pipelines

47

100

Electric Power Systems

47A

100

Transmission/Distribution Substations

47B

100

Transmission/Distribution Lines

47C

100

Fossil Fuel Plants

47D

100

Cogeneration Plants

47E

100

Hydroelectric Plants

48

100

Natural Gas Facilities

48A

252

Earth Retaining Structures

48B

227

Pipelines

48C

100

Liquefied Natural Gas

49

257

Port/Harbor Facilities

49A

257

Waterfront Facilities

49B

253

Crane/Cargo Handling

49C

100

Fuel Facilities

50

100

Heavy Industrial Facilities

50A

100

Pulp and Paper

50B

100

Steel Mill

50C

100

Mining

50D

100

Cement Mill

51

100

Light Industrial Facilities

51A

245

High Technology

51B

100

Telecommunication

52

100

Mixed

52A

101

Wood Frame Single Wall

52B

101

Wood Frame Double Wall

53

100

Golf Country Club

54

100

Boats, Inside a Building (Marina)

55

266

Boats, Moored, less than 26 feet, Motor

56

267

Boats, Moored, less than 26 feet, Sail

57

266

Boats, Moored, 26-60 feet, Motor

58

267

Boats, Moored, 26-60 feet, Sail

59

266

Boats, Moored, greater than 60 feet, Motor

60

267

Boats, Moored, greater than 60 feet, Sail

61

257

Floating Structures

 

 

© 2016 AIR Worldwide. All rights reserved.

Click here for information about AIR Worldwide, including copyright, trademarks, confidentiality, and contact information.

Touchstone V3.0 Updated December 01, 2016